I've created a copy of a module (Ctrl+C, Ctrl+V) and made some modifications in the new module. Then I'd like to baseline it (the new one), but the version of the baseline follows the last baseline of the original module, despite the new module does not contain any baselines.
How can I reset the baseline counter to create a baseline version 1.0 in the new module?
Thank you!
GaborMoizes - Tue Sep 07 04:17:33 EDT 2010 |
|
Re: Reset baseline version Mathias Mamsch - Tue Sep 07 16:04:31 EDT 2010
In the telelogic kitchen tools you will find a script that enables you to copy a module with their absolute numbers intact. This way you will loose your history, but you will end up with a freshly created module. This might be the only simple way to do it.
Regards, Mathias
Mathias Mamsch, IT-QBase GmbH, Consultant for Requirement Engineering and D00RS
|
|
Re: Reset baseline version SystemAdmin - Tue Oct 05 10:53:32 EDT 2010
In your case, before doing the copy (ctrl c, ctrl v), I would have done a baseline of my original module.
Then do a copy of this baseline and you will have a copy of your original module with baseline version set to 0.0
Regards
David
|
|
Re: Reset baseline version Mathias Mamsch - Tue Oct 05 11:43:51 EDT 2010 SystemAdmin - Tue Oct 05 10:53:32 EDT 2010
In your case, before doing the copy (ctrl c, ctrl v), I would have done a baseline of my original module.
Then do a copy of this baseline and you will have a copy of your original module with baseline version set to 0.0
Regards
David
Note however that the "Copy Baseline" script will recreate the objects in the module giving all your objects different Absolute Numbers. So it is not a "real" copy. Regards, Mathias